Cisco 交换机综合实例(五)

发布者:上海IT外包来源:http://www.lanmon.net点击数:3820

本实例综合性很强,基本上包含了Cisco交换机的所有交换技术,如有问题可以与站长联系

第五部分:

Catalyst 5505  的配置

下面给出配置清单

Enter password:  Console> enable Enter password:  Console> (enable) set system name 5505-WC-F2 System name set.
5505-WC-F2> (enable) set system location 2nd Floor Wiring Closet System location set.
5505-WC-F2> (enable) set system contact [email protected] System contact set.
5505-WC-F2> (enable) set time 04/30/1999 10:00:00 Fri Apr 30 1999, 10:00:00 
5505-WC-F2> (enable) set password Enter old password:  Enter new password:  Retype new password:  Password changed.
5505-WC-F2> (enable) set enablepass Enter old password:  Enter new password:  Retype new password:  Password changed.
5505-WC-F2> (enable) set banner motd % 5505-WC-F2 (Catalyst 5505) Access Restricted % MOTD banner set
5505-WC-F2> (enable) set interface sc0 10.10.1.30/24 Interface sc0 IP address set.
5505-WC-F2> (enable) set ip route default 10.10.1.1 Route added.
5505-WC-F2> (enable) set ip dns server 10.10.10.100 10.10.10.100 added to DNS server table as primary server.
5505-WC-F2> (enable) set ip dns domain bigcorp.com  Default DNS domain name set to bigcorp.com
5505-WC-F2> (enable) set ip dns enable DNS is enabled
5505-WC-F2> (enable) set vtp domain BigCorp mode client VTP domain BigCorp modified
5505-WC-F2> (enable) set module name 1 Supervisor III Module name set.
5505-WC-F2> (enable) set port name 1/1-4 FEC ISL Trunk Ports 1/1-4 name set.
5505-WC-F2> (enable) set port speed 1/1-4 100 Ports 1/1-4 transmission speed set to 100Mbps.
5505-WC-F2> (enable) set port duplex 1/1-4 full Ports 1/1-4 set to full-duplex.
5505-WC-F2> (enable) set port flowcontrol 1/1-4 send off Ports 1/1-4 flow control send administration status set to off
(ports will not send flowcontrol to far end)
5505-WC-F2> (enable) set port flowcontrol 1/1-4 receive off Ports 1/1-4 flow control receive administration status set to off
(ports will not allow far end to send flowcontrol)
5505-WC-F2> (enable) set port negotiation 1/1-4 enable Ports 1/1-4 negotiation enabled
5505-WC-F2> (enable) set port channel 1/1-4 desirable Port(s) 1/1-4 channel mode set to desirable.
5505-WC-F2> (enable) set trunk 1/1 desirable isl Port(s) 1/1 trunk mode set to desirable.
Port(s) 1/1 trunk type set to isl.
5505-WC-F2> (enable) set module name 2 QA 100Mb Hosts Module name set.
5505-WC-F2> (enable) set port name 2/1-4 QA Sparc20 Port 2/1-4 name set.
5505-WC-F2> (enable) set port name 2/5-12 QA NT Workstation Ports 2/5-12 name set.
5505-WC-F2> (enable) set port speed 2/1-12 100 Ports 2/1-12 transmission speed set to 100Mbps.
5505-WC-F2> (enable) set port duplex 2/1-12 full Ports 2/1-12 set to full-duplex.
5505-WC-F2> (enable) set port flowcontrol 2/1-12 send desired Ports 2/1-12 flow control send administration status set to desired
(ports will send flowcontrol to far end if far end supports it)
5505-WC-F2> (enable) set port flowcontrol 2/1-12 receive desired Ports 2/1-12 flow control receive administration status set to desired
(ports will allow far end to send flowcontrol if far end supports it)
5505-WC-F2> (enable) set port channel 2/1-12 off Port(s) 2/1-12 channel mode set to off.
5505-WC-F2> (enable) set trunk 2/1-12 off Port(s) 2/1-12 trunk mode set to off.
5505-WC-F2> (enable) set spantree portfast 2/1-12 enable Warning: Spantree port fast start should only be enabled on ports connected
to a single host. Connecting hubs, concentrators, switches, bridges, etc. to
a fast start port can cause temporary spanning tree loops. Use with caution.
 
Spantree ports 2/1-12 fast start enabled.
5505-WC-F2> (enable) set vlan 40 2/1-12 VLAN 40 modified.
VLAN 1 modified.
VLAN  Mod/Ports
---- -----------------------
40    1/1-4
      2/1-12
      
5505-WC-F2> (enable) set module name 3 QA 10Mb Hosts Module name set.
5505-WC-F2> (enable) set port name 3/1-48 QA WinNT PC Ports 3/1-48 name set.
5505-WC-F2> (enable) set port duplex 3/1-48 full Ports 3/1-48 set to full-duplex.
5505-WC-F2> (enable) set spantree portfast 3/1-48 enable Warning: Spantree port fast start should only be enabled on ports connected
to a single host. Connecting hubs, concentrators, switches, bridges, etc. to
a fast start port can cause temporary spanning tree loops. Use with caution.
 
Spantree ports 3/1-48 fast start enabled.
5505-WC-F2> (enable) set vlan 40 3/1-48 VLAN 40 modified.
VLAN 1 modified.
VLAN  Mod/Ports
---- -----------------------
40    1/1-4
      2/1-12
      3/1-48
      
5505-WC-F2> (enable) set module name 4 Corp/F&A 10Mb Hosts Module name set.
5505-WC-F2> (enable) set port name 4/1-12 Corp Win98 PC Ports 4/1-12 name set.
5505-WC-F2> (enable) set port name 4/13-48 F&A Win98 PC Ports 4/13-48 name set.
5505-WC-F2> (enable) set port duplex 4/1-48 full Ports 4/1-48 set to full-duplex.
5505-WC-F2> (enable) set spantree portfast 4/1-48 enable Warning: Spantree port fast start should only be enabled on ports connected
to a single host. Connecting hubs, concentrators, switches, bridges, etc. to
a fast start port can cause temporary spanning tree loops. Use with caution.
 
Spantree ports 4/1-48 fast start enabled.
5505-WC-F2> (enable) set vlan 10 4/1-12 VLAN 10 modified.
VLAN 1 modified.
VLAN  Mod/Ports
---- -----------------------
10    1/1-4
      4/1-12
      
5505-WC-F2> (enable) set vlan 50 4/13-48 VLAN 50 modified.
VLAN 1 modified.
VLAN  Mod/Ports
---- -----------------------
50    1/1-4
      4/13-48
      
5505-WC-F2> (enable) set module name 5 S&M 10Mb Hosts Module name set.
5505-WC-F2> (enable) set port name 5/1-48 S&M Win98 PC Ports 5/1-48 name set.
5505-WC-F2> (enable) set port duplex 5/1-48 full Ports 5/1-48 set to full-duplex.
5505-WC-F2> (enable) set spantree portfast 5/1-48 enable Warning: Spantree port fast start should only be enabled on ports connected
to a single host. Connecting hubs, concentrators, switches, bridges, etc. to
a fast start port can cause temporary spanning tree loops. Use with caution.
 
Spantree ports 5/1-48 fast start enabled.
5505-WC-F2> (enable) set vlan 60 5/1-48 VLAN 60 modified.
VLAN 1 modified.
VLAN  Mod/Ports
---- -----------------------
60    1/1-4
      5/1-48
 
5505-WC-F2> (enable) 
全文结束
说明:
以上典型配置有很多已经是厂商停产产品,但是,不少设备往往还有运行,关于该设备的配置或者方案优化,你可以联系蓝盟,我们的资深工程师会给你意外的惊喜!上海蓝盟网络技术有限公司于2002年成立,业务涵盖IT外包、电脑维护、网络维护、网管外包、驻场服务、人员派驻、应急支持、系统集成、网络搬迁、网络升级、数据备份、综合布线、电脑维修、计算机维护、计算机维修,网络改造、网络整理、网络调试、局域网组建、 应急上门、数据恢复、网络咨询、服务管理、运维咨询、ITIL培训、ITSS咨询等,拥有近200名工程师,正在为近500家客户提供“一站式” 的IT外包服务。网址:www.lanmon.com www.lanmon.net 官方微博:http://weibo.com/lanmon2012 咨询电话:4008200159 蓝色学苑:www.bluestudy.net